Vasopressors or fluids in early septic shock (Registro nro. 23346)

000 -Cabecera
Campo de control interno 03054nam a2200265 4500
001 - Número de control
control field ESSALUD
005 - Fecha y hora de la última transacción
Campo de control 20261117121556.0
007 - Tipo material - Descripcion fisica - info general
Tipo material - Descripcion fisica - info general ta
008 - Elementos de Longitud Fija - Información General
Elementos de Longitud Fija - Información t pe ||||| |||| 00| 0 spa d
040 ## - Origen de la Catalogación
Origen de la Catalogación BMG
041 ## - Idioma
Idioma eng
100 ## - Autor
Autor ARISE FLUIDS
Rol del Autor Autor
9 (RLIN) 56017
245 ## - Titulo
Titulo Vasopressors or fluids in early septic shock
300 ## - Páginas
Paginación páginas: 1387-1398
520 ## - Resumen
Resumen Background: The optimal approach to early resuscitation in septic shock is unknown. Equipoise exists between the use of larger volumes of intravenous fluids to restore perfusion and the use of early vasopressor therapy along with smaller volumes of fluids to minimize potential harm from excess fluid.<br/>Methods: We randomly assigned adult patients who presented to the emergency department with septic shock to receive either fluids at restricted volumes and early vasopressor therapy (vasopressor group) or higher volumes of fluids and later vasopressor therapy (fluids group) for at least 6 hours and up to 24 hours. The primary outcome was days alive and out of the hospital from randomization to day 90.<br/>Results: A total of 1000 patients underwent randomization, with 499 assigned to the vasopressor group and 501 to the fluids group. Informed consent was not obtained for 37 patients, which left 963 patients in the intention-to-treat population (481 in the vasopressor group and 482 in the fluids group). Three patients in the fluids group were lost to follow-up for the primary outcome. In the first 24 hours after randomization, patients in the vasopressor group received less intravenous fluid than those in the fluids group (median difference, −1108 ml; 95% confidence interval [CI], −1395 to −850). The percentage of patients who received vasopressors was higher by 18.9 percentage points (95% CI, 13.3 to 24.5) in the vasopressor group. The median number of days alive and out of the hospital at day 90 was 76 (interquartile range, 55 to 83) in the vasopressor group and 76 (interquartile range, 55 to 82) in the fluids group (difference, 0.0 days; 95% CI, −2.7 to 2.7; P=1.00). Adverse events occurred in similar percentages of patients in the two groups, except for pulmonary edema (0.6% in the vasopressor group vs. 5.0% in the fluids group; P<0.001).<br/>Conclusions: Among adult patients who presented to the emergency department with septic shock, an approach that involved restricted fluid volume and early vasopressors did not result in a greater number of days alive and out of the hospital at day 90 than an approach involving greater fluid volume and later administration of vasopressors.
650 ## - Temas - Descriptores
Temas - Descriptores CHOQUE
9 (RLIN) 44162
650 ## - Temas - Descriptores
Temas - Descriptores NEUMOLOGIA
9 (RLIN) 25628
650 ## - Temas - Descriptores
Temas - Descriptores CUIDADOS INTENSIVOS
9 (RLIN) 5208
650 ## - Temas - Descriptores
Temas - Descriptores MEDICINA HOSPITALARIA
9 (RLIN) 55973
650 ## - Temas - Descriptores
Temas - Descriptores ENFERMEDADES INFECCIOSAS
9 (RLIN) 6776
700 ## - Autor Personal
Autor Personal ANZICS Clinical Trials Group
9 (RLIN) 56018
700 ## - Autor Personal
Autor Personal ACEM Clinical Trials Network
9 (RLIN) 56019
773 0# - Revista (Relacion con el numero)
Host Biblionumber 22717
Host Itemnumber 22828
Ciudad, Editorial Massachusetts NEJM Group
Codigo barras item/ejemplar NEJM024
Titulo de la Revista The New England Journal of Medicine
Número de control de registro ESSALUD
ISSN 0028-4793
942 ## - Elementos de Koha
Tipo de Documento Artículos
Fecha procesamiento 2026-11-17
Catalogador sqb

No hay ítems disponibles.